Water leak detector Success AT-407N

Application of water leak detector Success AT-407N

Advanced acoustic water leak detector for metal and non-metal underground pipelines laying under paved and unpaved surfaces.

Portable acoustic water leak detector Success AT-407N is designed to locate leaks from underground pipelines of heat, water, gas, oil supply systems located at a depth of up to 3 m with or without pipe trench.

High-sensitive ground microphone ensures detection of leakage noise in pipes with pressure starting from 2 bar.


Acoustic method of water leak detection.



Benefits of water leak detector Success AT-407N


Features of AP-027M receiver


Acoustic sensor AD-227 allows to find the leak


Acoustic sensor AD-227 operation for water leaks detection

Move along the pipe to the supposed place of water leakage. During the operation there will be the following indication on the screen:

  1. The signal is low on the screen and in the headphones, there is no signifi cant noise.
  2. The closer to the place of leakage the higher is the signal on the screen and the louder is the sound in the headphones.
  3. The operator is above the place of leakage, the signal is maximum.
  4. The signal is less, it means the leakage was behind.

Water leak detector Success AT-407N is recommended for application in the following industries


Specifications of AP-027M receiver

Parameter Tracing Leak detection
Type of accepted signal Uninterrupted /pulse Uninterrupted signal
Frequencies of the receiver’s filter Central frequency of quasi-resonant filter 50…60 Hz, 100…450 Hz through 50 Hz, 120…540 Hz through 60 Hz, 512 Hz / 1024 Hz / 8192 Hz / 33 kHz - Range limitation "below" 0,1 / 0,15 / 0,21 / 0,31 / 0,45 / 0,65 / 0,95 / 1, 38 kHz;
- Range limitation "above" 2,00 / 1,38 / 0,95 / 0,65 / 0,45 / 0,31 / 0,21 / 0, 15 kHz
"Broadband" (operating mode) 0,05…8,6 kHz 0,09…2,20 kHz
Gain factor 100 dB
Visual indication Liquid-crystal display-symbols and meaning of the chosen modes and parameters:
- animated (moving) scale of the output signal level;
- digital value and animated (moving) scale of the output signal level;
- graphic (moving diagram) of the output signal level;
- frequency content of the output signal level;
- digital and graphic display of output signal levels kept in the "memory"
Sound indication - Headphones natural broadband or filtered signal
- Headphones-synthesized sound. Frequency modulation;
- Built-in emitter - synthesized sound. Frequency modulation
-
Supply - voltage 4...7 V;
- alkaline batteries АА type 1,5 V (4 pcs.)
Time of continuous operation not less than 20 hours
Automatic shutdown when the device is not active After 30 minutes of inactivity
Ambient temperature -20...+50°С
Ingress protection rating IP54
Weight of the electronic unit 0,46 kg
Receiver AP-027M dimensions 220x102x42 mm

Basic set

Name Quantity
1 Receiver AP-027M 1 pcs.
2 Acoustic sensor AD-227 1 pcs.
3 Headphones 1 pcs.
4 Operation manual 1 pcs.