info@technoac.com

Two-channel data logging thermometer DT-529

Overview

Features

Professional, digital, two-channel data logging thermometer DT-529 is used to measure the temperature of liquid, dry, gaseous medium by penetration of the probe in the medium (penetration measurement), contact measurement of the solid surfaces temperature (surface measurement), measurement of the relative humidity of the gaseous non-aggressive medium, atmospheric pressure measurement, air flow speed measurement.

DT-529 has the ability to connect to a PC to set up the device and store the recorded data, saving the values on SD card, which can be viewed in the form of tables or graphs. Thermometers have a measurement resolution of 0.01°C.

DT-529, depending on the order are in set with hi-prescision probes of different use.

Two-channel data logging thermometer 529 can be simultaneously mounted with detachable probes of different types connected to the first channel and the resistance thermometer or sensor with unified current output 4...20 mA, connected to the second channel.

DT-529 has the function of automatic reading the type of connected probe.

Purpose

DT-529 is used for highly precise measurement and logging of the temperature, humidity and dew point temperature by direct contact with the measurement object.

Due to the possibility of changing the probe, accurate measurements can be carried out for almost any media: liquid, dry, solid.

Two measurement channels and a logging function allow you to collect and store on the memory card detailed information about all measurements.

The software supplied with the device allows you to store and check the data on a computer.

Since one of the channels allows you to connect sensors and resistance thermometers with a current from 4 to 20 mA, we recommend the DT-529 as a logger for the joint use of sensors manufactured by TECHNO-AC and sensors of other brands.

Improved devices allow using high-precision probes for:

Calibration

All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.

Contact us if you want to check id DT-5 are certified for your country.



Specifications

Parameter Value
Limits of absolute additional instrumental error when measuring temperature caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, °C ±0,5
Limits of absolute additional instrumental error when measuring relative humidity caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ±0,5
Limits of absolute additional instrumental error when measuring current signal caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ±0.5×Δ abs. instr.
DC power supply voltage, V 3
External DC power supply voltage, V 5
The length of the connecting cable between the electronic unit and the probe, m 1
Weight of the electronic unit, less than, kg 0,2
Overall dimensions of the electronic unit, less than mm 180x70x27
Average error-free running time, at least, h 10000
Average operational life, at least, years 10


Standard set

Basic set

Name Quantity
1 Two-channel data logging thermometer DT-529 1 pcs.
2 1.5 V battery, type AA 2 pcs.
3 Operation manual (in English) 1 pcs.
4 Packaging 1 pcs.

Accessories

Name
1 Battery charger
2 Battery AA 1.2 V (2850 mA) - 2 pcs.
3 Case 53141 for a thermometer with 1 probe
4 Case 53142 for a thermometer with 2 probes
5 Case 53143 for a thermometer with 3 probes
6 Case 53134 for thermometer with 4 probes