Metal and non-metal pipeline locator with water leak detection function Success TPT-522N

Application of metal and non-metal pipeline locator with water leak detection function Success TPT-522N


One device combines an electromagnetic signal transmitter and an impact mechanism.


Features of metal and non-metal pipeline locator with water leak detection function Success TPT-522N

Metal and PVC pipe locator with water leak detection function Success TPT-522N – multifunctional 3 in 1 set:

1. Cable and pipe locator with acoustic sensor

Acoustic method is used to locate metal and non-metal pipelines, when tracing metal pipelines in conditions of high industrial interference, when tracing is difficult (if there are nearby communications, such as pipes, cables, metal objects; industrial interference, such as power lines, railway and tram lines, etc.).

2. Cable and pipe locator with electromagnetic sensor

3. Water leak detector with acoustic sensor


Features of AP-027M receiver


Features of AG-144.1 transmitter


Description of impact device UM-112

It is used for producing the sound impacts on the pipe surface for acoustic tracing of non-metal and metal pipelines. The sound produced with the impact device is spread along the pipeline and, through the ground, picked-up with the acoustic sensor connected to the receiver. After being amplified and filtered in the receiver, the sensor signal is indicated on the screen and transmitted to headphones.


AP-027M operation for utilities tracing

Move to the supposed utility location - an energized cable or a pipe. During the operation there will be information on the screen and sound in the headphones.

  1. The signal is low on the screen and in the headphones, it means the utility is far away from the operator.
  2. The closer to the utility the higher is the signal on the screen and the louder is the sound in the headphones.
  3. The operator is above the utility, the signal is maximum.
  4. The signal is less, it means the leakage was behind.

Acoustic sensor AD-227 operation for water leaks detection

Move along the pipe to the supposed place of water leakage. During the operation there will be the following indication on the screen:

  1. The signal is low on the screen and in the headphones, there is no signifi cant noise.
  2. The closer to the place of leakage the higher is the signal on the screen and the louder is the sound in the headphones.
  3. The operator is above the place of leakage, the signal is maximum.
  4. The signal is less, it means the leakage was behind.

Metal and PVC pipe locator with water leak detection function Success TPT-522N is recommended for application in the following industries


Specifications of AP-027M receiver

Parameter Tracing Leak detection
Type of accepted signal Uninterrupted /pulse Uninterrupted signal
Frequencies of the receiver’s filter Central frequency of quasi-resonant filter 50…60 Hz, 100…450 Hz through 50 Hz, 120…540 Hz through 60 Hz, 512 Hz / 1024 Hz / 8192 Hz / 33 kHz - Range limitation "below" 0,1 / 0,15 / 0,21 / 0,31 / 0,45 / 0,65 / 0,95 / 1, 38 kHz;
- Range limitation "above" 2,00 / 1,38 / 0,95 / 0,65 / 0,45 / 0,31 / 0,21 / 0, 15 kHz
"Broadband" (operating mode) 0,05…8,6 kHz 0,09…2,20 kHz
Gain factor 100 dB
Visual indication Liquid-crystal display-symbols and meaning of the chosen modes and parameters:
- animated (moving) scale of the output signal level;
- digital value and animated (moving) scale of the output signal level;
- graphic (moving diagram) of the output signal level;
- frequency content of the output signal level;
- digital and graphic display of output signal levels kept in the "memory"
Sound indication - Headphones natural broadband or filtered signal
- Headphones-synthesized sound. Frequency modulation;
- Built-in emitter - synthesized sound. Frequency modulation
-
Supply - voltage 4...7 V;
- alkaline batteries АА type 1,5 V (4 pcs.)
Time of continuous operation not less than 20 hours
Automatic shutdown when the device is not active After 30 minutes of inactivity
Ambient temperature -20...+50°С
Ingress protection rating IP54
Weight of the electronic unit 0,46 kg
Receiver AP-027M dimensions 220x102x42 mm

Specifications of AG-144.1 transmitter

Parameter Value
Transmitted signal frequencies, Hz
Frequencies SIN f1 / f2 / f3, ±0.1% 512 / 1024 / 8192
Shock repetition frequencies, low / medium / high frequency 0.5 / 1 / 2
Transmission modes
"SIN" "contin" Continuous sine transmission
"SIN" "_П_" Short-time pulsing of sine signal
- pulse duration, ms 100
- pulse repetition rate, Hz 1
"SIN" "3 freq" Three-frequency – sine signal pulsing with repetition of frequencies f1, f2, f3
- pulse duration, ms 100
- pulse repetition rate, Hz 2
"SHOCK" pulse duration Transmission of shock pulses, set automatically
Output parameters of sine transmission
Maximum output voltage, V:  
- at autonomous power supply 220
- with the 12/24 V external accumulator added 330
- at power supply from the network unit 140
Output power provided due to self-matching (fully-charged accumulators), ±20%:  
- at autonomous power supply (12/24 V)  
Modes:
- continuously
- pulses 8192 Hz and 3 freq
Pout, W 7.5 15 30 60
Rload, Ω 0.1...300 0.15...660 0.3...1.300 0.6...660
Modes:
- pulses 512 and 1,024 Hz
Pout, W 15 30 60 120
Rload, Ω 0.15...660 0.3...330 0.6...660 1.2...330
- with supply voltage built up to 36 V with the use of the 12/24 V external accumulator  
Modes:
- continuously
- pulses 8192 Hz and 3 freq
Pout, W 45 90
Rload, Ω 0.45...2.000 0.9...1.000
Modes:
- pulses 512 and 1,024 Hz
Pout, W 90 180
Rload, Ω 0.9...1.000 1.8...500
- from the network power supply unit  
Modes:
- continuously
- pulses 8192 Hz and 3 freq
Pout, W 18 36
Rload, Ω 1.8...800 0.4...400
Modes:
- pulses 512 and 1,024 Hz
Pout, W 36 72
Rload, Ω 0.4...400 0.7...200
Permissible load resistance any (0…∞)
Current limitation on «low-resistance» loads. Broken cable capacitance operation
Matching with load Automatic, providing for the target power gaining in the load
Power supply sources
Built-in accumulator set Two lead-acid sealed accumulators 12 V/7 Ah (AGM technology) with switch-over: 12V/14Ah or 24V/7Ah
Network unit for accumulators operation or charging Output voltage 15 V, output current up to 6.7 A
Source duration depending on power that was initially gained as a result of self-matching (ambient temperature 0°С), minimum
- continuous generation Duration, hours 1.7 3.7
Pout, W 60 autonomously / 90 with add. acc. 30 autonomously / 45 with add. acc.
- one-frequency pulses Duration, hours 8 18
Pout, W 120 autonomously / 180 with add. acc. 60 autonomously / 90 with add. acc.
- three-frequency pulses Duration, hours 8 18
Pout, W 60 autonomously / 90 with add. acc. 30 autonomously / 45 with add. acc.
- transmission of shock pulses Duration, hours 8 18
Pout, W "hf"
2 Hz
"mf"
1 Hz
Maximum time of self-contained accumulators charging, hours 4
Functional Specific Features
Automatic functions - self-matching (target power gaining in the load);
- specific program for transmitting antenna control;
- built-in automatic charger;
- "autodetection" of transmitting antenna and shock device connection and disconnection
Automatic disabling of transmission (charging) - when accumulators are charged below the permitted rate (prevention of deep irreversible discharge);
- when external source voltage does not correspond to the transmission / charging mode;
- when the network source mode is switched over during charging;
- when the output is short-circuited during matching;
- when the transmission mode does not correspond to the transmitting antenna or shock device presence / absence at the output
Automatic repeated matching - when the steady-state output power increases due toinadvertent drop in load resistance;
- when the frequency / transmission mode "SIN" is switched over;
- when certain source voltage changes occur
Types of connected loads at transmission "SIN" - direct connection to the facility with current "return" via the cable cord or armature;
- direct connection to the facility with current "return" via ground by means of a ground pin;
- loop connection with the use of the transmitting loop antenna at the 8192 Hz (selected automatically at antenna connection);
- loop connection with the use of the loop clamp (selection of the cable from a bundle)
Design parameters
Output power amplifier pulsed, technology CLASS D(BD), coefficient of efficiency > 80%
Indication Light-emitting diodes:
- three-colour "source" and "out";
- source voltage and status;
- output power and status red « »;
- possible or present "dangerous" output voltage (>24V)
Control Push-button switches -

three-position switches:
- "FREQ" of the output signal "SIN, Hz" or "SHOCK" of pulse repetition;
- "MODE", "SIN" – sine transmission type;
- "START" of transmission / charging and selection of half / full power "SIN" available for this source

two-position switches – "SOURCE":
- "EXTERN" – capacity / power build-up with the use of the external accumulator or selection of operation / charging from the network unit;
- "INTERN" – selection of the 12 V / 24 V internal source voltage for changing the specified power (by 4 times in autonomous mode)

button « »:
- loading in potentially "dangerous" mode with "unlimited" output voltage (Uout can be >24 V) 
Overall dimensions of the electronic unit (case), max., mm 220х160х145
Weight of the electronic unit, max., kg 8.2
Operation conditions
Permissible ambient temperature range at operation -30…+60°С
Climatic protection class IP54 (dust-water-shock-proof casing)

Basic set of metal and non-metal pipeline locator with water leak detection function Success TPT-522N

Name Quantity
1 Receiver AP-027M 1 pcs.
2 Transmitter АG-144.1 1 pcs.
3 Inductive antenna IEM-301.3 1 pcs.
4 Electromagnetic sensor EMD-247 1 pcs.
5 Acoustic sensor AD-227 1 pcs.
6 Impact device UM-112 1 pcs.
7 Headphones 1 pcs.
8 Contact magnetic AG120.02.090 2 pcs.
9 Grounding rod AG110.02.004 2 pcs.
10 Operation manual 1 pcs.