×
info@technoac.com

Cable and pipe locator Success AG-319G

Description of cable and pipe locator Success AG-319G

The set for inspection of buried utilities (cable lines, metal pipelines, and other utilities made of conductive materials).

The set includes a monoblock receiver with a large LCD screen, which indicates actual position of cable and pipe and automatically measures burial depth up to 10 m, as well as current rate.

Built-in GPS/GLONASS module to store the coordinates of located utility.

"Probe" mode for locating NON-METALLIC utilities with pipe sonde (optional).


The most powerful multi-frequency transmitter with a range up to 10 km.


Contact and non-contact connection to utility.


Application of cable and pipe locator Success AG-319G


Features of AP-019.3 receiver


Features of AG-120 transmitter


Functional features of AP-019.3 in different operation modes

"Route" mode

"Route" mode screen is considered to be main. Utility axis position, burial depth and current of the utility are indicated on LCD screen. Detection of utility is performed in semi-automatic mode clearly and quickly.

"Graph" mode

Moving graph of signal strength level at the selected frequency is indicated together with utility position. "Graph" mode is used when the signal is too low or when the electromagnetic field is distorted.

"Graph+" mode

This mode provides the location of energized power cables which cross another located utility.

"MIN&MAX" mode

The "MIN&MAX" mode on the graphs of signal level changes helps to locate the center of a cable or pipe more accurately. Also it helps indicating several utilities laying nearby.

"R.dis." modes (Relative distance to the utility)

These modes are used when cables and pipes are positioned close to each other to measure burial depth of located utilities.

"2 frequencies" mode

In the "2 frequencies mode", the cable condition and pipeline protection diagnostic is performed using the transmitter.

Linking utilities to a terrain map using the GPS/GLONASS module

Using the built-in GPS/GLONASS module, the current coordinates of the receiver are detected. By pressing a key on the control panel, the date, time, current coordinates and measured parameters of the main points are stored in the receiver’s RAM: the burial depth and current rate.

The saved data are uploaded to PC for mapping and further processing: editing the connection between points (track construction), saving the track to a database, as well as to a KML or CSV file.


MapProgram

This program is designed for reading of saved points from the AP-019.3 device, displaying locations on Google Maps and Yandex Maps, editing of interrelation between points (construction of a track), saving a track to a database, as well as to KML-file and CSV-file. All points are stored in database. The database is stored in the folder with exe file. The name of the database is "GPSdb".

To work with the data saved in the receiver AP-019.3 the device is connected to a computer using a USB cable.

System requirements for the computer

MapProgram window

All the information about the program is contained in the "Help" section.


UtilityLoc program

The UtilityLoc program is designed for the AP-019.3 receiver and has greater functionality for saving data in publicly available formats than the MapProgram. Users have access to its updates for the duration of its use.

System requirements for the computer

The disc comes with a key to activate the software.

For information on the cost of the program and its license, please contact our managers.


AP-019.3 operation for utilities tracing

During the operation there will be the following indication on the screen:

  1. There is indication in the form of point on the screen, it means the utility is far away from the operator. It’s necessary to move towards the point.
  2. The utility axis is appeared on the screen and its position relative to the operator.
  3. The axis in the middle shows that the operator is above the utility. There is automatically calculation of the depth and current.

Cable and pipe locator Success AG-319G is recommended for application in the following industries


Specifications of AP-019.3 receiver

Parameter Value
Receiver Quasi resonant filter centre frequency 50(60) / 100(120) / 512 / 1024 / 8192 / 32768 Hz
“Wide band” frequency band 0,04...8 kHz
Frequency range "Radio" 8...40 kHz
Sonde frequency 512 Hz
Dynamic range of incoming signal 120 dB
Number of embedded sensors 4
Max. sensitivity (in "Graph" mode: F0 = incoherent distortion +10 dB is 31…35 kHz) 5 mkA at 1m distance
Data log capacity 2300 "points"
Connected external sensors CI-105, HP-117, DODK-117, DKI-117 (made by "TECHNO-AC")
Sensitivity control - Auto-for 2D display "Route";
- Semi-automatic or manual (optional) - for the "Graphic", "Graphic+", MIN&MAX and "Sonde";
- Automatic or manual (optional) - for the "2F" mode
Determination the burial depth of the route - Automatically in "Route" mode 0...10 m;
- By pressing a button in "Sonde" mode
Burial depth identification accuracy ±5%
Identification of the effective current in the route Automatically in "Route" mode 0.001...49.99 A
Accuracy of current measurement of received signal ±5%
Support of energy saving (intermittent) modes of the route locating transmitters At combined work with the route locating transmitters made by "TECHNO-AC" ("Pulse" mode)
Visual indication Graphic display LCD display, 320x240 pix., with LED backlight
Induced parameters - 2D visualization of the route location relative to the device;
- Graphics of the signal level from sensors;
- Route burial depth;
- Signal current;
- Signal strength;
- Settings and control parameters
Audio indication Built-in speaker:
- natural filtered sound;
- buttons sound indication
Power source - 4...7 V (4 type C batteries);
- External Power Bank – optional
Time of continuous operation from the single battery set Not less than 20 hours
Automatic shutdown when the device is not active After 30 minutes of inactivity
Operating /storage temperature range -20...60°С / -30...60°С
Dust and water protection degree IP54
Dimensions 330x140x700 mm
Weight (excluding batteries) 2,4 kg

Specifications of AG-120 transmitter

Parameter Value
Frequency of generated signal
Frequencies f1, f2, f3 (three frequencies fixed in memory), Hz Range 200…9999
(selected in the range with a resolution of 1 Hz and accuracy of ±0,05% Hz and input in the power-independent memory)
Frequency f4 (one "temporary"), Hz Range 200…9999
(selected instead of one of the "fixed", not input to the memory, exists while the power is on)
Output parameters
Output current
Maximum in manual mode:
- continuous and two frequencies generation, А 10
- pulse generation, А 15
Maximum output voltage:
- when working in safe mode, V 24
- under internal power supply, V 220 (170 when "2F")
- with added external accumulator 12 V, V 330 (260 when "2F")
- when supplied from power adapter, V 140 (110 when "2F") 
Maximum output power when accumulators are fully charged:
- under internal power supply or from external accumulator 24 V, W 120 continuous at a load of 1,2…300 Ohm / 180 pulsed at a load of 0,8…200 Ohm
- with added external accumulator 12 V, W 180 continuous at a load of 1,8…450 Ohm / 270 pulsed at a load of 1,2…300 Ohm
- from power adapter, W 70 at a load of 0,7…200 Ohm
NOTE. When incompletely charged or (and) frequencies above the "logarithmic middle point" of the range (1,4 kHz) the reduction of the maximum power with an increase of frequency and load resistance is possible at no more than 3 dB.
Resistance range for matched loads, broader than
For minimum specified current (0,1 А):
- for internal power, Ohm 4…2200 (4…1700 when "2F")
- with external accumulator 12 V added, Ohm 4…3300 (4…2600 when "2F")
For maximum continuous current (10 А):  
- for internal power, Ohm 0…1,2
- with external accumulator 12 V added, Ohm 0…1,8
For maximum pulsed current (15 А):
- for internal power, Ohm 0…0,8
- with external accumulator 12 V added, Ohm 0…1,2
Matching with the load - automatic, providing achieving of the specified current in the load;
- manual (buttons « » or « »)
Design parameters
Output power amplifier Pulsed, technology CLASS D(BD);
Efficiency factor > 80%
LED-based superbright digital indicators of high temperature range - all supply voltages;
- modes and settings;
- power resource;
- OUTPUT MULTIMETER: "output voltage", "current in load", "load resistance", "power in load"
Control Nine-button keyboard and external power switch with generation indicator providing work under rain with closed cover (due to parameter setup "memorizing"), intuitive interface
Dimensions of electronic block (case), maximum, mm 305х270х194
Weight of electronic block, maximum, kg 12
Operating temperature range, °С -30…+50

Basic set

Name Quantity
1 Receiver АP-019.3 1 pcs.
2 Transmitter АG-120 1 pcs.
3 Inductive antenna IEM-301.3 1 pcs.
4 Contact magnetic AG120.02.090 2 pcs.
5 Grounding rod AG110.02.004 2 pcs.
6 Operation manual 1 pcs.