Cable and pipe locator Success AG-317G

Description of cable and pipe locator Success AG-317G

The set is designed for accurate location of underground utilities and their depth measurement (power/signal cable lines, armored fiber optic cables, pipes made of conductive materials), search for defects in cable lines, survey the ground before the excavation works in the shortest time and with great reliability and prevent damage to engineering utilities.

The set includes a monoblock receiver with a large LCD screen, which indicates actual position of cable and pipe and automatically measures burial depth up to 10 m, as well as current rate. Built-in GPS/GLONASS module to store the coordinates of located utility. "Probe" mode for locating NON-METALLIC utilities with pipe sonde (optional).

The set features the latest AG-107 autonomous transmitter with built-in batteries, LCD display, and built-in inductive antenna, for tracing utilities with a non-contact method.


Transmitter output power up to 60 W.


Application of cable and pipe locator Success AG-317G


Features of AP-019.3 receiver


Features of AG-107 transmitter


Functional features of AP-019.3 in different operation modes

"Route" mode

"Route" mode screen is considered to be main. Utility axis position, burial depth and current of the utility are indicated on LCD screen. Detection of utility is performed in semi-automatic mode clearly and quickly.

"Graph" mode

Moving graph of signal strength level at the selected frequency is indicated together with utility position. "Graph" mode is used when the signal is too low or when the electromagnetic field is distorted.

"Graph+" mode

This mode provides the location of energized power cables which cross another located utility.

"MIN&MAX" mode

The "MIN&MAX" mode on the graphs of signal level changes helps to locate the center of a cable or pipe more accurately. Also it helps indicating several utilities laying nearby.

"R.dis." modes (Relative distance to the utility)

These modes are used when cables and pipes are positioned close to each other to measure burial depth of located utilities.

"2 frequencies" mode

In the "2 frequencies mode", the cable condition and pipeline protection diagnostic is performed using the transmitter.

Linking utilities to a terrain map using the GPS/GLONASS module

Using the built-in GPS/GLONASS module, the current coordinates of the receiver are detected. By pressing a key on the control panel, the date, time, current coordinates and measured parameters of the main points are stored in the receiver’s RAM: the burial depth and current rate.

The saved data are uploaded to PC for mapping and further processing: editing the connection between points (track construction), saving the track to a database, as well as to a KML or CSV file.


MapProgram

This program is designed for reading of saved points from the AP-019.3 device, displaying locations on Google Maps and Yandex Maps, editing of interrelation between points (construction of a track), saving a track to a database, as well as to KML-file and CSV-file. All points are stored in database. The database is stored in the folder with exe file. The name of the database is "GPSdb".

To work with the data saved in the receiver AP-019.3 the device is connected to a computer using a USB cable.

System requirements for the computer

MapProgram window

All the information about the program is contained in the "Help" section.


UtilityLoc program

The UtilityLoc program is designed for the AP-019.3 receiver and has greater functionality for saving data in publicly available formats than the MapProgram. Users have access to its updates for the duration of its use.

System requirements for the computer

The disc comes with a key to activate the software.

For information on the cost of the program and its license, please contact our managers.


AP-019.3 operation for utilities tracing

During the operation there will be the following indication on the screen:

  1. There is indication in the form of point on the screen, it means the utility is far away from the operator. It’s necessary to move towards the point.
  2. The utility axis is appeared on the screen and its position relative to the operator.
  3. The axis in the middle shows that the operator is above the utility. There is automatically calculation of the depth and current.

Cable and pipe locator Success AG-317G is recommended for application in the following industries


Specifications of AP-019.3 receiver

Parameter Value
Receiver Quasi resonant filter centre frequency 50(60) / 100(120) / 512 / 1024 / 8192 / 32768 Hz
“Wide band” frequency band 0,04...8 kHz
Frequency range "Radio" 8...40 kHz
Sonde frequency 512 Hz
Dynamic range of incoming signal 120 dB
Number of embedded sensors 4
Max. sensitivity (in "Graph" mode: F0 = incoherent distortion +10 dB is 31…35 kHz) 5 mkA at 1m distance
Data log capacity 2300 "points"
Connected external sensors CI-105, HP-117, DODK-117, DKI-117 (made by "TECHNO-AC")
Sensitivity control - Auto-for 2D display "Route";
- Semi-automatic or manual (optional) - for the "Graphic", "Graphic+", MIN&MAX and "Sonde";
- Automatic or manual (optional) - for the "2F" mode
Determination the burial depth of the route - Automatically in "Route" mode 0...10 m;
- By pressing a button in "Sonde" mode
Burial depth identification accuracy ±5%
Identification of the effective current in the route Automatically in "Route" mode 0.001...49.99 A
Accuracy of current measurement of received signal ±5%
Support of energy saving (intermittent) modes of the route locating transmitters At combined work with the route locating transmitters made by "TECHNO-AC" ("Pulse" mode)
Visual indication Graphic display LCD display, 320x240 pix., with LED backlight
Induced parameters - 2D visualization of the route location relative to the device;
- Graphics of the signal level from sensors;
- Route burial depth;
- Signal current;
- Signal strength;
- Settings and control parameters
Audio indication Built-in speaker:
- natural filtered sound;
- buttons sound indication
Power source - 4...7 V (4 type C batteries);
- External Power Bank – optional
Time of continuous operation from the single battery set Not less than 20 hours
Automatic shutdown when the device is not active After 30 minutes of inactivity
Operating /storage temperature range -20...60°С / -30...60°С
Dust and water protection degree IP54
Dimensions 330x140x700 mm
Weight (excluding batteries) 2,4 kg

Specifications of AG-107 transmitter

Parameter Value
The frequencies of the continuous "Co" or pulse "Pu" signal, Hz ± 0,1% - "kHz"
Load "clips" or "clamp" 512 - "0.5" / 1024 - "1.0" / 8192 - "8.2" / 32768 - "33"
"Antenna" modes 8192 - "8.2" / 32768 - "33" for "In" and 8192 - "8.2" for "An"
Operating modes
"Antenna" mode Internal transmitting inductor "In"
"Modulation" modes (special form signal) - Pulse "Pu" (short-term transmissions of the sine signals);
- Transmission duration 0,12 sec.;
- Transmissions repetition frequency 1 Hz
- Dual-frequency "2F" (simultaneous frequency generation 1024 Hz, 8192 Hz);
- Amplitudes ratio 4/1 (respectively)
Output parameters under power supply voltage 12…15V
Output current, А
Restricted by the program under manual increment, ≥ 5 - at frequency 512 Hz "0.5" / 1024 Hz "1.0" / 8192 Hz "8.2" / "2F"
3 - at frequency 32768 Hz "33"
Set by the program for automatic adjustment with the external load of "clips" or "clamp", ≥ 0,1
Maximum output voltage, V
Depending on "modulation", ≥ 48 - in the dual-frequency modulation mode "2F"
60 - in other modes
Maximum output power, W
Restricted by the program, ≥ - 30 - In the continuous "Co" and pulse "Pu" modes at load resistance up to 120Ω;
- In dual - frequency mode "2F" at load resistance up to 77Ω
60 - At pulse mode "Pu" at load resistance up to 60Ω
Power supply sources
Operating range of the supply voltages - Minimally acceptable voltage - 10 V;
- Maximum allowed voltage for operation - 15 V
Accumulator 8 LiFePO4 26700 3,2 V accumulators
Charger - Charges up to a voltage of 14.6 V with a current of up to 10 A;
- Oscillation simultaneously with charging
External power supply sources (optional) - Voltage 10...15 V, power ≥ 80 W;
- For example, car batteries "12 V"
Operating time ("life cycle") When operating from the built-in accumulator, 1.2 hours in the "Co" and "2F" at 30 W initital output power or 5 hours in "Pu" mode at original output power 60 W
With the external power supply is fully conditioned by this external energy source characteristics therefore under mains supply operating time is unlimited
Operational characteristics
An automatic control over the output voltage during oscillation process Proportional control over the output power depending on the "energy potential" of the power supply source
Automatic shutdowns of the device At power supply voltage in the "stop" mode < 8 V
At power supply voltage > 15,5 V
In case of short circuit of the output during the adjustment process (actuation of the hardware safety system of the terminal amplifier)
In case of non-compliance of the oscillation mode settings depending on whether the external antenna is installed in the output or not (the switch to the "stop" mode)
In case of "long" (≈100 sec.) downtime in the "stop" mode (if the buttons are not pushed)
Adjustment with load Automatic, up to the reaching of the specific consumption rate or attainment of the load current: ≥ 0,1 А
Manual (via buttons LESS / MORE "« »") after the automatic adjustment
Connection options to the communication under examination "Contact" connection with "earth return"
"Non-contact" connection with application of the internal transmitting antenna "In"
"Non-contact" connection with application of the external transmitting antenna "An" (signal intensity is higher and communication access is more convenient compared to the built-in transmitting antenna "In")
"Non-contact" connection using the transmitting induction "clamp" (selection of the cable from the bunch us possible)
Electromagnetic compatibility
Classification in accordance with the Russian State Standard (GOST) 51318.22-2006 Class A
Structural parameters
Power output amplifier - The technology - updated CLASS D;
- Efficiency to 85%
LED indicators Separate light-emitting diodes indicating parameters and modes
Digital indicator displaying the modes and parameters values and also showing output parameters of the "MULTIMETER" measurements, e.g.: output voltage (V), load current (А), load power (W) and load resistance (Ω /kΩ)
Overall dimensions of the electronic unit (case), not more than, mm 216х180х105
The weight of the electronic unit, not more than, kg 2
Operating conditions
The admissible environment temperatures range when in operation -30…+60°С
Ingress protection rating IP65

Basic set of cable and pipe locator Success AG-317G

Name Quantity
1 Receiver АP-019.3 1 pcs.
2 Transmitter АG-107 1 pcs.
3 Contact magnetic AG120.02.090 2 pcs.
4 Grounding rod AG110.02.004 2 pcs.
5 Operation manual 1 pcs.