Features
Digital thermometer DT-511 is used to measure the temperature of different medium, relative humidity of the air by direct contact of the probe with measurement object.
The device has two measuring channels for connecting two probes at the same time and displaying information from both of them.
Thermometer consists of electronic unit and replaceable probes.
As thermosensitive elements in probes thermocouples are used.
As measuring element in relative humidity probes capacitive humidity sensors are used.
- Simultaneous measurement of humidity and temperature in any combination through two channels with one device.
- Measuring the temperature with resolution 0,1°С.
- Measuring the relative humidity with resolution 0,1%.
- Changeable probe.
- Working simultaneously with two probes.
- 9 memory cells for storing measurement readings.
- Measuring the atmospheric pressure.
- Displaying the temperature of the thermal compensation sensor on the screen.
- Displaying the air temperature when using the humidity probe.
- Fixating measured temperature and humidity in the device's memory.
- Displaying the average temperature and humidity for a given number of measurements.
- Displaying the maximum temperature and humidity (for a given number of measurements).
- Displaying the minimum temperature and humidity (for a given number of measurements).
- Setting measured temperature and humidity limits.
- Sound indication after reaching the set level of measured temperature and humidity.
- Automatic saving when switching off the current, averaged, max, min supply voltage, remaining operating time of the device.
- 1 year manufacturer's warranty.
- Powered by standard AA batteries.
Purpose
DT-511 is used for highly precise measurement of temperature, humidity and dew point temperature by direct contact with the measurement object.
Due to the possibility of changing the probe, measurements can be carried out for almost any media: liquid, dry, solid.
Improved devices allow using high-precision probes for:
- high-precision surface measurements;
- high-precision air temperature measurements;
- work with thermocouples of types K, L, B, R, S;
- high-precision atmospheric pressure measurements;
- simultaneous high-precision measurement of temperature and humidity.
Calibration
All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.
Contact us if you want to check id DT-5 are certified for your country.
Specifications
Parameter | Value |
---|---|
Measured temperature range | -100...+1800 (depends on the type of used probe) |
Relative instrumental error | ±0.5% + least significant digit value |
Resolution | 0.1°C |
Number of replaceable probes types | 24 |
Measured relative humidity range, % | 0...100 |
Absolute instrumental error of relative humidity measurement, % | 3 |
Terms of use | -20...+50°C |
Relative humidity | less than 80% at T=35°C |
Atmospheric pressure | 86...106 kPa |
Voltage | 1.5x2 V |
Connectable probes

Penetration probe PP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe PP-300
- Temperature measuring range, °C: -40…+300
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe PP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe EPP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe EPP-300
- Temperature measuring range, °C: -40…+300
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe EPP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe EPP-1000
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe EPP-1500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe PP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Penetration probe VPP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Air probe AP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Air probe AP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Air probe AP-1000
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

High-precision air probe HPAP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to 0°C and from +50 to +100°C;
- absolute instrumental error ±0.2°C in the range from 0 to +50°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C

Surface probe SP-150
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Surface probe SP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Surface probe SP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Surface probe SP-1000
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Surface probe BSP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Surface probe BSP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

High-temperature surface probe HTSP-300
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C; - relative instrumental error ±(2 + (*))% in the range over +100°C

High-temperature surface probe HTSP-500
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C; - relative instrumental error ±(2 + (*))% in the range over +100°C

High-temperature surface probe HTSP-1000
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

High-precision surface probe HPSP-150
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

High-precision surface probe HPSP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

High-precision surface probe HPSP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C

Thermocouple probe TCP (L) ***
- Temperature measuring range, °C: -100…+800
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **

Thermocouple probe TCP (K) ***
- Temperature measuring range, °C: -100…+1300
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **

Thermocouple probe TCP (B) ***
- Temperature measuring range, °C: +600…+1800
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **

Thermocouple probe TCP (R) ***
- Temperature measuring range, °C: 0…+1600
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **

Thermocouple probe TCP (S) ***
- Temperature measuring range, °C: 0…+1600
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
* Resolution for DT-511 - 0,1°C.
** Without accounting thermocouple instrumental errors.
*** Probe is used to connect with external thermocouple of specific type (L, K, B, R, or S).
Basic set
№ | Name | Quantity |
---|---|---|
1 | Digital thermometer DT-511 | 1 pcs. |
2 | 1.5 V battery, type AA | 2 pcs. |
3 | Operation manual (in English) | 1 pcs. |
4 | Packaging | 1 pcs. |
Accessories
№ | Name |
---|---|
1 | Battery charger for AA batteries |
2 | Battery AA 1.2 V (2850 mA) |
3 | Case 53141 for a thermometer with 1 probe |
4 | Case 53142 for a thermometer with 2 probes |
5 | Case 53143 for a thermometer with 3 probes |
6 | Case 53134 for thermometer with 4 probes |