DT-529 - professional, digital, two-channel data logging thermometer

DT-529 - professional, digital, two-channel data logging thermometer

Modern multifunctional devices for measuring temperature and relative humidity.

Categories: Digital thermometers

Overview

Features

Professional, digital, two-channel data logging thermometer DT-529 is used to measure the temperature of liquid, dry, gaseous medium by penetration of the probe in the medium (penetration measurement), contact measurement of the solid surfaces temperature (surface measurement), measurement of the relative humidity of the gaseous non-aggressive medium, atmospheric pressure measurement, air flow speed measurement.

DT-529 has the ability to connect to a PC to set up the device and store the recorded data, saving the values on SD card, which can be viewed in the form of tables or graphs. Thermometers have a measurement resolution of 0.01°C.

DT-529, depending on the order are in set with hi-prescision probes of different use.

Two-channel data logging thermometer 529 can be simultaneously mounted with detachable probes of different types connected to the first channel and the resistance thermometer or sensor with unified current output 4...20 mA, connected to the second channel.

DT-529 has the function of automatic reading the type of connected probe.

  • Accurate measurement of physical quantities with resolution 1; 0.1; 0.01 (can be set in menu).
  • Detachable probe.
  • Simultaneous use of two probes for measurement.
  • Dew point calculation.
  • Saving measurement readings on device’s SD-card.
  • Fast logging of readings at intervals from 1 second to 23 hours 59 minutes 59 seconds.
  • Displaying statistical data of measurement readings, such as max, min readings over the last 90 measurements.
  • Installed batteries or accumulators charge state indication.
  • Setting of the sound signal when the preset limit point of measurement quantity is exceeded.
  • Automatic hibernation after set downtime.
  • Automatic switch off after set downtime.
  • Graphic displaying the measurement readings change over time.
  • Readings in the form of the table or graph saved on SD-card.
  • Protection of batteries from over-discharging.
  • Connection with PC for device setting and saved data checking.
  • External power connection.
  • Automatic saving when switching off the current, averaged, max, min supply voltage, remaining operating time of the device.
  • Humidity, atmospheric pressure, luminosity measurement.
  • Simultaneous measurement of temperature and humidity.
  • 1 year manufacturer's warranty.
  • Powered by standard AA batteries.
  • Graphic color display.

Purpose

DT-529 is used for highly precise measurement and logging of the temperature, humidity and dew point temperature by direct contact with the measurement object.

Due to the possibility of changing the probe, accurate measurements can be carried out for almost any media: liquid, dry, solid.

Two measurement channels and a logging function allow you to collect and store on the memory card detailed information about all measurements.

The software supplied with the device allows you to store and check the data on a computer.

Since one of the channels allows you to connect sensors and resistance thermometers with a current from 4 to 20 mA, we recommend the DT-529 as a logger for the joint use of sensors manufactured by TECHNO-AC and sensors of other brands.

Improved devices allow using high-precision probes for:

  • high-precision surface measurements;
  • high-precision air temperature measurements;
  • high-precision atmospheric pressure measurements;
  • work with thermocouples of types K, L, B, R, S;
  • work with sensors of other manufacturers;
  • simultaneous high-precision measurement of temperature and humidity.

Calibration

All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.

Contact us if you want to check id DT-5 are certified for your country.


Specifications

Parameter Value
Limits of absolute additional instrumental error when measuring temperature caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, °C ±0,5
Limits of absolute additional instrumental error when measuring relative humidity caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ±0,5
Limits of absolute additional instrumental error when measuring current signal caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ±0.5×Δ abs. instr.
DC power supply voltage, V 3
External DC power supply voltage, V 5
The length of the connecting cable between the electronic unit and the probe, m 1
Weight of the electronic unit, less than, kg 0,2
Overall dimensions of the electronic unit, less than mm 180x70x27
Average error-free running time, at least, h 10000
Average operational life, at least, years 10

Connectable probes

Penetration probe PP-150

Penetration probe PP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-300

Penetration probe PP-300

  • Temperature measuring range, °C: -40…+300
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-500

Penetration probe PP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-150

Penetration probe EPP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-300

Penetration probe EPP-300

  • Temperature measuring range, °C: -40…+300
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-500

Penetration probe EPP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1000

Penetration probe EPP-1000

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1500

Penetration probe EPP-1500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP

Penetration probe PP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe VPP

Penetration probe VPP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-150

Air probe AP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-500

Air probe AP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-1000

Air probe AP-1000

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
High-precision air probe HPAP

High-precision air probe HPAP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to 0°C and from +50 to +100°C;
    - absolute instrumental error ±0.2°C in the range from 0 to +50°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Surface probe SP-150

Surface probe SP-150

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-300

Surface probe SP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-500

Surface probe SP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-1000

Surface probe SP-1000

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-300

Surface probe BSP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-500

Surface probe BSP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-300

High-temperature surface probe HTSP-300

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-500

High-temperature surface probe HTSP-500

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-1000

High-temperature surface probe HTSP-1000

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-150

High-precision surface probe HPSP-150

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-300

High-precision surface probe HPSP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-500

High-precision surface probe HPSP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Thermocouple probe TCP (L) ***

Thermocouple probe TCP (L) ***

  • Temperature measuring range, °C: -100…+800
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (K) ***

Thermocouple probe TCP (K) ***

  • Temperature measuring range, °C: -100…+1300
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (B) ***

Thermocouple probe TCP (B) ***

  • Temperature measuring range, °C: +600…+1800
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (R) ***

Thermocouple probe TCP (R) ***

  • Temperature measuring range, °C: 0…+1600
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (S) ***

Thermocouple probe TCP (S) ***

  • Temperature measuring range, °C: 0…+1600
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Humidity and temperature probe THP-150

Humidity and temperature probe THP-150

  • Temperature measuring range, °C: -20…+85
  • Relative humidity measuring range, %: 0,1…100
  • Thermal inertia, s: 5
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±0,5°C;
    - relative error ±3%
Humidity and temperature probe THP-500

Humidity and temperature probe THP-500

  • Temperature measuring range, °C: -20…+85
  • Relative humidity measuring range, %: 0,1…100
  • Thermal inertia, s: 5
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±0,5°C;
    - relative error ±3%
Humidity and temperature probe THP-1000

Humidity and temperature probe THP-1000

  • Temperature measuring range, °C: -20…+85
  • Relative humidity measuring range, %: 0,1…100
  • Thermal inertia, s: 5
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±0,5°C;
    - relative error ±3%
Humidity and temperature probe PTHP

Humidity and temperature probe PTHP

  • Temperature measuring range, °C: -20…+85
  • Relative humidity measuring range, %: 0,1…100
  • Thermal inertia, s: 5
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±0,5°C;
    - relative error ±3%
Flexible temperature & humidity probe FTHP

Flexible temperature & humidity probe FTHP

  • Temperature measuring range, °C: -20…+85
  • Relative humidity measuring range, %: 0,1…100
  • Thermal inertia, s: 5
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±0,2°C;
    - relative error ±3%
Atmospheric pressure probe APP

Atmospheric pressure probe APP

  • Temperature measuring range, °C: -20...+65
  • Atmospheric pressure measuring range, mm Hg: 225...820
  • Limits of instrumental error of thermometer in set with probe:
    - absolute error ±2°С;
    - absolute instrumental error ±2,3 mm Hg (from 0 to +65°С and from 225 to 525 mm Hg);
    - absolute instrumental error ±1,9 mm Hg (from 0 to +65°С and from 526 to 820 mm Hg);
    - absolute instrumental error ±3 mm Hg (from -20 to 0°С and from 225 to 820 mm Hg)

* Resolution for DT-529 - 0,1°C.

** Without accounting thermocouple instrumental errors.

*** Probe is used to connect with external thermocouple of specific type (L, K, B, R, or S).


Standard set

Basic set

Name Quantity
1 Two-channel data logging thermometer DT-529 1 pcs.
2 1.5 V battery, type AA 2 pcs.
3 Operation manual (in English) 1 pcs.
4 Packaging 1 pcs.

Accessories

Name
1 Battery charger
2 Battery AA 1.2 V (2850 mA) - 2 pcs.
3 Case 53141 for a thermometer with 1 probe
4 Case 53142 for a thermometer with 2 probes
5 Case 53143 for a thermometer with 3 probes
6 Case 53134 for thermometer with 4 probes