Two-channel data logging thermometer DT-529
DT-529 - professional, digital, two-channel data logging thermometer
DT-529 - professional, digital, two-channel data logging thermometer
Modern multifunctional devices for measuring temperature and relative humidity.
Overview
Features
Professional, digital, two-channel data logging thermometer DT-529 is used to measure the temperature of liquid, dry, gaseous medium by penetration of the probe in the medium (penetration measurement), contact measurement of the solid surfaces temperature (surface measurement), measurement of the relative humidity of the gaseous non-aggressive medium, atmospheric pressure measurement, air flow speed measurement.
DT-529 has the ability to connect to a PC to set up the device and store the recorded data, saving the values on SD card, which can be viewed in the form of tables or graphs. Thermometers have a measurement resolution of 0.01°C.
DT-529, depending on the order are in set with hi-prescision probes of different use.
Two-channel data logging thermometer 529 can be simultaneously mounted with detachable probes of different types connected to the first channel and the resistance thermometer or sensor with unified current output 4...20 mA, connected to the second channel.
DT-529 has the function of automatic reading the type of connected probe.
- Accurate measurement of physical quantities with resolution 1; 0.1; 0.01 (can be set in menu).
- Detachable probe.
- Simultaneous use of two probes for measurement.
- Dew point calculation.
- Saving measurement readings on device’s SD-card.
- Fast logging of readings at intervals from 1 second to 23 hours 59 minutes 59 seconds.
- Displaying statistical data of measurement readings, such as max, min readings over the last 90 measurements.
- Installed batteries or accumulators charge state indication.
- Setting of the sound signal when the preset limit point of measurement quantity is exceeded.
- Automatic hibernation after set downtime.
- Automatic switch off after set downtime.
- Graphic displaying the measurement readings change over time.
- Readings in the form of the table or graph saved on SD-card.
- Protection of batteries from over-discharging.
- Connection with PC for device setting and saved data checking.
- External power connection.
- Automatic saving when switching off the current, averaged, max, min supply voltage, remaining operating time of the device.
- Humidity, atmospheric pressure, luminosity measurement.
- Simultaneous measurement of temperature and humidity.
- 1 year manufacturer's warranty.
- Powered by standard AA batteries.
- Graphic color display.
Purpose
DT-529 is used for highly precise measurement and logging of the temperature, humidity and dew point temperature by direct contact with the measurement object.
Due to the possibility of changing the probe, accurate measurements can be carried out for almost any media: liquid, dry, solid.
Two measurement channels and a logging function allow you to collect and store on the memory card detailed information about all measurements.
The software supplied with the device allows you to store and check the data on a computer.
Since one of the channels allows you to connect sensors and resistance thermometers with a current from 4 to 20 mA, we recommend the DT-529 as a logger for the joint use of sensors manufactured by TECHNO-AC and sensors of other brands.
Improved devices allow using high-precision probes for:
- high-precision surface measurements;
- high-precision air temperature measurements;
- high-precision atmospheric pressure measurements;
- work with thermocouples of types K, L, B, R, S;
- work with sensors of other manufacturers;
- simultaneous high-precision measurement of temperature and humidity.
Calibration
All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.
Contact us if you want to check id DT-5 are certified for your country.
Specifications
Parameter | Value |
---|---|
Limits of absolute additional instrumental error when measuring temperature caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, °C | ±0,5 |
Limits of absolute additional instrumental error when measuring relative humidity caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % | ±0,5 |
Limits of absolute additional instrumental error when measuring current signal caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % | ±0.5×Δ abs. instr. |
DC power supply voltage, V | 3 |
External DC power supply voltage, V | 5 |
The length of the connecting cable between the electronic unit and the probe, m | 1 |
Weight of the electronic unit, less than, kg | 0,2 |
Overall dimensions of the electronic unit, less than mm | 180x70x27 |
Average error-free running time, at least, h | 10000 |
Average operational life, at least, years | 10 |
Connectable probes
Penetration probe PP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-300
- Temperature measuring range, °C: -40…+300
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-300
- Temperature measuring range, °C: -40…+300
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1000
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe VPP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 6
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-150
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-500
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-1000
- Temperature measuring range, °C: -40…+600
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to +100°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
High-precision air probe HPAP
- Temperature measuring range, °C: -40…+200
- Thermal inertia, s: 2
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C in the range from -40 to 0°C and from +50 to +100°C;
- absolute instrumental error ±0.2°C in the range from 0 to +50°C;
- relative instrumental error ±(0.5 + (*))% in the range over +100°C
Surface probe SP-150
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-1000
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-300
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-500
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-1000
- Temperature measuring range, °C: -40…+500
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to +100°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-150
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-300
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-500
- Temperature measuring range, °C: -40…+250
- Thermal inertia, s: 10
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
- absolute instrumental error ±0.5°C in the range from 0 to +50°C;
- relative instrumental error ±(2 + (*))% in the range over +100°C
Thermocouple probe TCP (L) ***
- Temperature measuring range, °C: -100…+800
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
Thermocouple probe TCP (K) ***
- Temperature measuring range, °C: -100…+1300
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
Thermocouple probe TCP (B) ***
- Temperature measuring range, °C: +600…+1800
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
Thermocouple probe TCP (R) ***
- Temperature measuring range, °C: 0…+1600
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
Thermocouple probe TCP (S) ***
- Temperature measuring range, °C: 0…+1600
- Limits of instrumental error of thermometer in set with probe:
- absolute instrumental error ±0.5°C **
Humidity and temperature probe THP-150
- Temperature measuring range, °C: -20…+85
- Relative humidity measuring range, %: 0,1…100
- Thermal inertia, s: 5
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±0,5°C;
- relative error ±3%
Humidity and temperature probe THP-500
- Temperature measuring range, °C: -20…+85
- Relative humidity measuring range, %: 0,1…100
- Thermal inertia, s: 5
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±0,5°C;
- relative error ±3%
Humidity and temperature probe THP-1000
- Temperature measuring range, °C: -20…+85
- Relative humidity measuring range, %: 0,1…100
- Thermal inertia, s: 5
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±0,5°C;
- relative error ±3%
Humidity and temperature probe PTHP
- Temperature measuring range, °C: -20…+85
- Relative humidity measuring range, %: 0,1…100
- Thermal inertia, s: 5
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±0,5°C;
- relative error ±3%
Flexible temperature & humidity probe FTHP
- Temperature measuring range, °C: -20…+85
- Relative humidity measuring range, %: 0,1…100
- Thermal inertia, s: 5
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±0,2°C;
- relative error ±3%
Atmospheric pressure probe APP
- Temperature measuring range, °C: -20...+65
- Atmospheric pressure measuring range, mm Hg: 225...820
- Limits of instrumental error of thermometer in set with probe:
- absolute error ±2°С;
- absolute instrumental error ±2,3 mm Hg (from 0 to +65°С and from 225 to 525 mm Hg);
- absolute instrumental error ±1,9 mm Hg (from 0 to +65°С and from 526 to 820 mm Hg);
- absolute instrumental error ±3 mm Hg (from -20 to 0°С and from 225 to 820 mm Hg)
* Resolution for DT-529 - 0,1°C.
** Without accounting thermocouple instrumental errors.
*** Probe is used to connect with external thermocouple of specific type (L, K, B, R, or S).
Standard set
Basic set
№ | Name | Quantity |
---|---|---|
1 | Two-channel data logging thermometer DT-529 | 1 pcs. |
2 | 1.5 V battery, type AA | 2 pcs. |
3 | Operation manual (in English) | 1 pcs. |
4 | Packaging | 1 pcs. |
Accessories
№ | Name |
---|---|
1 | Battery charger |
2 | Battery AA 1.2 V (2850 mA) - 2 pcs. |
3 | Case 53141 for a thermometer with 1 probe |
4 | Case 53142 for a thermometer with 2 probes |
5 | Case 53143 for a thermometer with 3 probes |
6 | Case 53134 for thermometer with 4 probes |