DT-506 - digital thermometer (thermohygrometer)

DT-506 - digital thermometer (thermohygrometer)

The device solves a wide range of tasks for controlling the temperature of various objects and the relative humidity of the air.

Categories: Digital thermometers

Overview

Features

Digital thermometer DT-506 is used to measure the temperature of different medium, relative humidity of the air by direct contact of the probe with measurement object.

While using humidity probes thermometers can calculate dew point temperature using the Goff - Gratch formula.

Digital thermometers consist of electronic unit and replaceable probes.

As thermosensitive elements in probes thermocouples are used.

This model works with an adapter for connecting thermocouples of types K, L, B, R, S.

  • Measurement of temperature with resolution 0,1°С.
  • Measurement of the relative humidity of the air with resolution 0,1°С.
  • Changeable probe.
  • Maximum temperature fixation.
  • Minimum temperature fixation.
  • Indicator readings fixation.
  • Dew point temperature calculation.
  • Large display with bright backlight.
  • 1 year manufacturer's warranty.
  • Powered by standard AA batteries.

Purpose

DT-506 is used for highly precise measurement of temperature, humidity and dew point temperature by direct contact with the measurement object.

Due to the possibility of changing the probe, measurements can be carried out for almost any media: liquid, dry, solid.

Improved devices allow using high-precision probes for:

  • high-precision surface measurements;
  • high-precision air temperature measurements;
  • dew point temperature calculation and measurement;
  • work with thermocouples of types K, L, B, R, S;
  • simultaneous high-precision measurement of temperature and humidity.

Calibration

All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.

Contact us if you want to check id DT-5 are certified for your country.


Specifications

Parameter Value
Measured temperature range -100...+1800 (depends on the type of used probe)
Relative instrumental error ±0.5% + least significant digit value
Resolution 0.1°C
Number of replaceable probes types 24
Measured relative humidity range, % 0...100
Absolute instrumental error of relative humidity measurement, % 3
Terms of use -20...+50°C
Voltage 1.5x2 V

Connectable probes

Penetration probe PP-150

Penetration probe PP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-300

Penetration probe PP-300

  • Temperature measuring range, °C: -40…+300
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP-500

Penetration probe PP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-150

Penetration probe EPP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-300

Penetration probe EPP-300

  • Temperature measuring range, °C: -40…+300
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-500

Penetration probe EPP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1000

Penetration probe EPP-1000

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe EPP-1500

Penetration probe EPP-1500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe PP

Penetration probe PP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Penetration probe VPP

Penetration probe VPP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 6
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-150

Air probe AP-150

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-500

Air probe AP-500

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Air probe AP-1000

Air probe AP-1000

  • Temperature measuring range, °C: -40…+600
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to +100°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
High-precision air probe HPAP

High-precision air probe HPAP

  • Temperature measuring range, °C: -40…+200
  • Thermal inertia, s: 2
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C in the range from -40 to 0°C and from +50 to +100°C;
    - absolute instrumental error ±0.2°C in the range from 0 to +50°C;
    - relative instrumental error ±(0.5 + (*))% in the range over +100°C
Surface probe SP-150

Surface probe SP-150

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-300

Surface probe SP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-500

Surface probe SP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe SP-1000

Surface probe SP-1000

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-300

Surface probe BSP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Surface probe BSP-500

Surface probe BSP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-300

High-temperature surface probe HTSP-300

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-500

High-temperature surface probe HTSP-500

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-temperature surface probe HTSP-1000

High-temperature surface probe HTSP-1000

  • Temperature measuring range, °C: -40…+500
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to +100°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-150

High-precision surface probe HPSP-150

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-300

High-precision surface probe HPSP-300

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
High-precision surface probe HPSP-500

High-precision surface probe HPSP-500

  • Temperature measuring range, °C: -40…+250
  • Thermal inertia, s: 10
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±2°C in the range from -40 to 0°C and +50 to +100°C;
    - absolute instrumental error ±0.5°C in the range from 0 to +50°C;
    - relative instrumental error ±(2 + (*))% in the range over +100°C
Thermocouple probe TCP (L) ***

Thermocouple probe TCP (L) ***

  • Temperature measuring range, °C: -100…+800
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (K) ***

Thermocouple probe TCP (K) ***

  • Temperature measuring range, °C: -100…+1300
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (B) ***

Thermocouple probe TCP (B) ***

  • Temperature measuring range, °C: +600…+1800
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (R) ***

Thermocouple probe TCP (R) ***

  • Temperature measuring range, °C: 0…+1600
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **
Thermocouple probe TCP (S) ***

Thermocouple probe TCP (S) ***

  • Temperature measuring range, °C: 0…+1600
  • Limits of instrumental error of thermometer in set with probe:
    - absolute instrumental error ±0.5°C **

* Resolution for DT-506 - 0,1°C.

** Without accounting thermocouple instrumental errors.

*** Probe is used to connect with external thermocouple of specific type (L, K, B, R, or S).


Standard set

Basic set

Name Quantity
1 Digital thermometer DT-506 1 pcs.
2 1.5 V battery, type AA 2 pcs.
3 Operation manual (in English) 1 pcs.
4 Packaging 1 pcs.

Accessories

Name
1 Battery charger for AA batteries
2 Battery AA 1.2 V (2850 mA)
3 Case 53141 for a thermometer with 1 probe
4 Case 53142 for a thermometer with 2 probes
5 Case 53143 for a thermometer with 3 probes
6 Case 53134 for thermometer with 4 probes

Video

Digital thermometers DT-504, DT-506, DT-509, DT-511

Review of digital thermometers DT-504, DT-506, DT-509, DT-511.

Download full product catalogue
Download