Detection and locating, measuring equipment
Water leak detectors, cable and pipe locators

Cable Fault Locator TDR RI-407

TDR RI-407 is intended for the following measurements on power cable lines:

  • cable length measurement and cable integrity tests;
  • measurement of the distance to the heterogeneity of the cable impedance or low-resistance fault, using TDR method;
  • measurement of the distance to the high-resistance fault, using the Arc Reflection Method (ARM) in complex with the high-voltage pulse generator (HVPG);
  • measurement of the distance to the high-resistance fault, using the Impulse Current Method (ICM) or Decay Method in complex with the high-voltage pulse generator (HVPG);
  • measurement of the velocity factor of the line at a known length.

Overview

High resolution

High resolution

ARM method

ARM method

Long measurement range

Long measurement range

ICM method

ICM method

Specifications

Specifications and characteristics
Implemented measurement methods TDR, ARM, ICM, DECAY
Display color 10.4" TFT 640 x 480 pixels, LED-backlight 400 cd/m2
Distance measurment range range range PF=1.500: 1 m … 256 km
Pulse Width 10 ns … 100 us
Pulse Amplitude 18 V, 86 V (on open circuit)
Distance measurement relative error 0.01% ... 0.2% (depending of sub-range)
Distance measurement absolute error 0.125 m (on sub-ranges <= 1 km) … 32 m (on 256 km sub-range)
Effective sampling rate 800 MHz
Input impedance 75 Ohm (fixed)
Attenuation overlap 73 dB
Asynchronous noise suppression averaging 1 … 64 times
Propagation Factor(PF) range PF=1.000 … 3.000
Synchronization ARM external (TRIG), internal (delay 0 …50 ms, step 0.2 ms)
Synchronization ICM, DECAY threshold level (-165 V … +165 V, step 2 V)
Non-volatile internal memory 300 waveforms, 500 PF values
Data exchange via USB-Flash
File types waveform (*.tdr, up to 8000 px), screenshot ( *.jpg)
User interface language Russian/English/ your language on request
Connectors TDR (BNC), TRIG (BNC), WAVE (BNC), USB-A
Power AC 12 V, built-in Li-Ion battery (7,2 ± 0,7)V 7,0A
Continuous running from the battery at least 6 hours. Continuous running via AC adapter is not limited
Overall dimensions 363 mm * 295 mm * 170 mm
Weight 3.7 kg
Working conditions
  • operating temperature range from -20 to 40 °C;
  • relative humidity 98%, at 25 °C;
  • transportation and storage conditions from -50 to 50 °C.

Standard set

  • Cable Fault Locator TDR RI-407 (tech. spec. 4221-009-23133821-15) - 1 item
  • AC Adapter 12 V - 1 item
  • Connecting cable 75 Ohm, 3 m, BNC.M - «Alligator clipclipclipclip» with a working width of 25.4 mm - 1 item
  • Connecting cable 75 Ohm, 1 m, BNC.M-BNC.M - 2 items
  • User Manual (tech. spec. 4221-009-23133821-15) - 1 item
  • CD-ROM with software - 1 item
  • Accessories bag - 1 item

Accessories

Transitional Device UP-1

Transitional Device UP-1

Purpose

Transitional Device UP-1 is a device used for electrical isolation between the measuring low-voltage TDR connector and energized cable line up to 380 V rms. UP-1 is compatible with any TDR instrument.

Specifications and Characteristics

  • The maximum allowable input voltage: 380 V RMS
  • Indication of voltage on the line: from 50 V
  • Overall dimensions: 120 mm * 65 mm * 40 mm
  • Weight: 0.2 kg
  • Working conditions:
    • operating temperature range from -20 to 40 °C
    • relative humidity 98%, at 25 °C
    • transportation and storage conditions from -50 to 50 °C.

Delivery Contents

  • Transitional Device UP-1 - 1 item
  • User Manual (tech. spec. 4221-009-23133821-15) - 1 item

Download


Operation manual